Inspection Procedure 3: The ready indicator does not illuminate even if the electric motor switch is turned to the START position.




PROBABLE CAUSES



  • Main battery discharged

DIAGNOSIS PROCEDURE


STEP 1. ?Check whether the diagnosis code is set.


Check if the diagnosis code is set to the EV-ECU.

Q. Is the diagnosis code set?

Carry out troubleshooting for the EV-ECU. (Refer to .)
Go to Step 2.

STEP 2. Check the main battery energy level gauge


Check that the level of the main battery is not in the E position (0 segment display).

Q. Is the check result normal?

Go to Step 3.

    Charge the main battery.

STEP 3. Check the trouble symptom.


Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction .)
Go to Step 1.