Inspection Procedure 3: The ready indicator does not illuminate even if the electric motor switch is turned to the START position.
PROBABLE CAUSES |
|
DIAGNOSIS PROCEDURE |
STEP 1. ?Check whether the diagnosis code is set. |
Check if the diagnosis code is set to the EV-ECU. |
Q.
Is the diagnosis code set?
|
Carry out troubleshooting for the EV-ECU. (Refer to .) |
|
Go to Step 2. |
|
STEP 2. Check the main battery energy level gauge |
Check that the level of the main battery is not in the E position (0 segment display). |
Q.
Is the check result normal?
|
Go to Step 3. |
|
|
|
STEP 3. Check the trouble symptom. |
Q.
Is the check result normal?
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction .) |
|
Go to Step 1. |
|