(1)Shut down the high voltage.
|
|
(2)Check that the following terminals are tightened to the specified torque. (Refer
to .)
- G-07, G-08, G-09 MCU high-voltage terminal
|
|
Q.
Is the check result normal?
|
|
Tighten the high-voltage terminal to the specified torque. Refer to .)
|
|
|
|
Check again if the diagnosis code is set to the EV-ECU.
|
|
(1)Erase the stored diagnosis code.
|
|
(2)Set the electric motor switch from the "LOCK" (OFF) position to the "ON" position.
|
|
(3)Set the electric motor switch to the "START" position, and start the electric motor
unit.
|
|
(4)Check if the diagnosis code is set.
|
|
Q.
Is the diagnosis code set?
|
|
Replace the MCU. (Refer to .) Then go to
Step 3.
|
|
|
|
The diagnosis is complete.
|
|
|
|
Check again if the diagnosis code is set to the MCU.
|
|
(1)Erase the stored diagnosis code.
|
|
(2)Set the electric motor switch from the "LOCK" (OFF) position to the "ON" position.
|
|
(3)Set the electric motor switch to the "START" position, and start the electric motor
unit.
|
|
(4)Check if the diagnosis code is set.
|
|
Q.
Is the diagnosis code set?
|
|
Replace the motor (electric motor unit). (Refer to .)
Then go to Step 4.
|
|
|
|
The diagnosis is complete.
|
|
|
|
Check again if the diagnosis code is set to the MCU.
|
|
(1)Erase the stored diagnosis code.
|
|
(2)Set the electric motor switch from the "LOCK" (OFF) position to the "ON" position.
|
|
(3)Set the electric motor switch to the "START" position, and start the electric motor
unit.
|
|
(4)Check if the diagnosis code is set.
|
|
Q.
Is the diagnosis code set?
|
|
The diagnosis is complete.
|
|
|