Check Condition
- 5 seconds elapsed after the on board charger control power supply voltage was more
than 10 V and less than 16 V.
|
|
Judgement Criterion
- For more than 3 seconds, the CAN communication data cannot be received from the
EV-ECU.
|
|
- The CAN bus is failed.
- The EV-ECU is failed.
- The on board charger is failed.
|
|
- Using M.U.T.-III, perform CAN bus line diagnosis.
|
|
Q.
Is the check result normal?
|
|
Repair CAN bus line (Refer to GROUP 54C - Troubleshooting - CAN
Bus Diagnostics Table ).
|
|
|
|
Q.
Is diagnosis code of EV-ECU system set?
|
|
Check EV-ECU system (Refer to ).
|
|
|
|
Q.
Is the diagnosis code set?
|
|
Replace the on board charger/DC-DC converter.
|
|
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|