RECOMMENDED TOOLS


caution
  • When refrigerant is charged, use the special tools for the EV30AN3 compressor to fill up the refrigerant, because it is different from the normal compressor oil. (If the normal compressor oil is mixed, a leakage may be resulted in.)
  • For the compressor oil and installation oil for the piping O-ring, use the oil MA68EV dedicated for the A/C compressor EV30AN3. If an oil other then the MA68EV is used, even if it is only a small amount, the electric insulation is considerably deteriorated and a leakage may occur.

RECOMMENDED TOOLS FOR REFRIGERANT CHARGE



1.To drain and charge the refrigerant, it is recommended that the following recovery equipment is used.

  • MOR405JH-type flon recovery equipment (part number: MZ204413)
    Follow the recovery equipment manufacturer's instructions on draining and charging the refrigerant.

2.The following commercial tools are recommended for charging the refrigerant and measuring the refrigerant pressure.

  • Gas charging set [part number: EA95 (R134a)]
  • Gas charging set case (part number: EA101CS-2)
  • Gauge manifold (part number: EA101N-1)
  • Valve for service can (refrigerant container) (part number: EA108N)
  • Adapter valve (part number: EA104AD-3)
    note Tightening the adapter valve handle (turning clockwise) opens the valve, and loosening it (turning anticlockwise) closes the valve.
  • Low-pressure quick joint (part number: EA413L)
  • High pressure quick joint (part number: EA413H)
  • Charging hose (red, part number EA104N-1)
  • Charging hose (blue, part number EA104N-2)
  • Charging hose (yellow, part number EA104N-3)
  • Vacuum pump (part number: EA112A)
  • Vacuum pump adapter (part number: EA112X)