1.To drain and charge the refrigerant, it is recommended that the following recovery equipment is used.
- MOR405JH-type flon recovery equipment (part number: MZ204413)
Follow the recovery equipment manufacturer's instructions on draining and charging the refrigerant.
|
|
2.The following commercial tools are recommended for charging the refrigerant and measuring the refrigerant pressure.
- Gas charging set [part number: EA95 (R134a)]
- Gas charging set case (part number: EA101CS-2)
- Gauge manifold (part number: EA101N-1)
- Valve for service can (refrigerant container) (part number: EA108N)
- Adapter valve (part number: EA104AD-3)
note |
Tightening the adapter valve handle (turning clockwise) opens the valve, and loosening it (turning anticlockwise) closes the valve.
|
- Low-pressure quick joint (part number: EA413L)
- High pressure quick joint (part number: EA413H)
- Charging hose (red, part number EA104N-1)
- Charging hose (blue, part number EA104N-2)
- Charging hose (yellow, part number EA104N-3)
- Vacuum pump (part number: EA112A)
- Vacuum pump adapter (part number: EA112X)
|