Input signal from the key reminder switch is used to operate the functions below. If the
signal is abnormal, these functions will not work normally.
|
|
- Ignition key reminder buzzer
- Keyless entry system
- Ignition key cylinder illumination lamp
- Room lamp
|
|
- Malfunction of the key reminder switch
- Malfunction of the ETACS-ECU
- Damaged harness wires and connectors
|
|
Q.
Is the check result normal?
Go to Step 2.
Repair the defective connector.
|
|
Refer to GROUP 54A, Ignition switch .
|
|
Q.
Is the check result normal?
|
|
Replace the key reminder switch.
|
|
|
|
(1)Disconnect the connector, and measure at the wiring harness side.
|
|
(2)Check the resistance between C-301 key reminder switch connector terminal No.4 and body
earth OK: Continuity exists (2 Ω or less)
Q.
Is the check result normal?
Go to Step 5.
Go to Step 4.
|
|
note |
Prior to the wiring harness inspection, check junction block connector C-120, and repair
if necessary.
|
- Check the earth wires for open circuit.
Q.
Is the check result normal?
The trouble can be an intermittent malfunction (Refer to GROUP 00, How to use
Troubleshooting/inspection Service Points - How to Cope with Intermittent
Malfunction ).
Repair the wiring harness.
|
|
Q.
Is the check result normal?
Go to Step 6.
Repair the defective connector.
|
|
- Check the input line for open circuit.
Q.
Is the check result normal?
Go to Step 7.
Repair the wiring harness.
|
|
Check that the keyless entry system works normally.
|
|
Q.
Is the check result normal?
|
|
The trouble can be an intermittent malfunction (Refer to GROUP 00, How to use
Troubleshooting/inspection Service Points - How to Cope with Intermittent
Malfunction ).
|
|
|
|
Replace the ETACS-ECU and register the ID codes (Refer to GROUP 54A, How to Register
Encrypted Code ).
|
|
|