Inspection Procedure 19: The power windows do not work normally by means of the multimode keyless entry function.
| caution | Before replacing the ECU, ensure that the power supply circuit, the earth circuit and the communication circuit are normal. |
OPERATION
PROBABLE CAUSES
- Malfunction of power window main switch
- Function setting error or no setting with a customisation
- Malfunction of ETACS-ECU
DIAGNOSTIC PROCEDURE
STEP 1. Confirm the operation of the power windows.
Q.
Is the check result normal?



STEP 2. Check the customisation
- P/W: O and C, D/M: O and C.
- P/W: C, D/M: O and C.
- D/M: O and C.
- P/W: O and C.
- P/W: C.
Q.
Is it set to other than "disabled"?



STEP 3. M.U.T.-III diagnosis code
Q.
Is the diagnosis code set?



STEP 4. Check of the troubles
Q.
Is the check result normal?