Remove the connection and clamp of oxygen sensor connector, and then use special tool oxygen sensor wrench (MB991953) to remove the oxygen sensor.
|
|
Use a drill (6.0 mm) to make a hole in the rivet to break it, and then remove the rivet.
|
|
Use a rivet tool shown in the illustration to connect the parts with rivets by the following procedures. 1.Insert the rivet into a corresponding location. 2.Set the rivet tool at a portion A of rivet. 3.While pushing the flange surface of the rivet onto parts to be fixed with the rivet tool, press the handle of the tool. 4.Thin part of portion A of the rivet will be cut off and the parts is fixed in position.
|
|
Tighten the oxygen sensor to the specified torque by using special tool oxygen sensor wrench (MB991953). Tightening torque: 50 ± 10 N·m
|