1.Move the stabilizer link ball joint stud back and forth for several times, install the
stud with nut, and measure the stabilizer link ball joint rotation torque using the preload
socket (Special tool: MB990326). Standard value: 0.5 to 2.9 N·m 2.When the measured value exceeds the standard range, replace the stabilizer link. 3.When the measured value is lower than the standard value, check the stabilizer link
ball joint that there is no looseness or gritty feeling. If there is no looseness or gritty
feeling, it is judged as usable.
|