Diagnosis Item 21: Diagnose when the M.U.T.-III cannot receive the data sent by combination meter



caution When servicing a CAN bus line, earth yourself by touching a metal object such as an unpainted water pipe. If you fail to do, a component connected to the CAN bus line may be broken.








FUNCTION




TROUBLE JUDGMENT CONDITIONS




TROUBLESHOOTING HINTS



  • Malfunction of the connector [joint connector (CAN1) or combination meter connector improperly connected]
  • Malfunction of the wiring harness [open circuit between the combination meter connector and the joint connector (CAN1), or power supply circuit to the combination meter]
  • Malfunction of the combination meter

DIAGNOSIS PROCEDURE


STEP 1. Connector check: C-105 joint connector (CAN1) and C-03 combination meter connector


caution The strand end of the twist wire should be within 10 cm from the connector. For details refer to .

Q. Is the check result normal?

Go to Step 2.
Repair the defective connector.

STEP 2. Check the wiring harness between C-03 combination meter connector and C-105 joint connector (CAN1)


caution Strictly observe the specified wiring harness repair procedure. For details refer to .
(1)Disconnect combination meter connector and joint connector (CAN1), and check the following wiring harness.
(2)Check that there is continuity between C-03 combination meter connector terminal No.14 and C-105 joint connector (CAN1) terminal No.3 <CAN_H>
OK: Continuity exists (2 Ω or less)
(3)Check that there is continuity between C-03 combination meter connector terminal No.15 and C-105 joint connector (CAN1) terminal No.14 <CAN_L>
OK: Continuity exists (2 Ω or less)

Q. Is the check result normal?

Check the power supply circuit of the combination meter. Refer to Group 54A - Combination meter - Troubleshooting .
Repair the wiring harness.