GENERAL INFORMATION



For the cooling method, a forced water-cooling circulation system is adopted and it has the following characteristics:


SPECIFICATIONS


Item
4B1
Cooling method
Water-cooled pressurised, forced circulation with electrical fan
Water pump
Type
Centrifugal impeller
Drive method
Drive belt
Thermostat
Type
Wax pellet with jiggle valve
Valve open temperature °C
82 ± 1.5
Radiator
Type
Pressurised corrugate type
Core size (width × height × thickness) mm
687.4 × 400 × 16
Performance kJ/h
201,800
Engine coolant
Specified coolant
DIA QUEEN SUPER LONG LIFE COOLANT or equivalent
Quantity (including 0.65 L in the radiator condenser tank) L
Approximately 7.5

CONSTRUCTION DIAGRAM