INITIALISATION PROCEDURE FOR LEARNING VALUE IN MPI ENGINE <PHEV>



Initialise learning values in the MPI engine when one of the following service operations is performed.

  • At replacing engine assembly. *
  • At replacing and cleaning injector.
  • At replacing and cleaning throttle body.
  • At replacing detonation sensor.

INITIALISATION PROCEDURE



caution To prevent damage to M.U.T.-III, always turn OFF the power supply mode of the electric motor switch before connecting or disconnecting M.U.T.-III.
1.After the power supply mode of the electric motor switch is OFF, connect the M.U.T.-III to the diagnosis connector.
2.Operate the electric motor switch without depressing the brake pedal and turn ON the power supply mode of electric motor switch.
3.Select "MPI/GDI/DIESEL" from System select Screen of the M.U.T.-III.
4.Select "Special Function" from MPI/GDI/DIESEL Screen.
5.Select "Learned value reset" from Special Function Screen.
6.Select "All learned value" from Learned value reset Screen
7.Initialise the learning value by pressing the "OK" button.