ENGINE CONTROL RELAY CONTINUITY CHECK



Tester connection terminal
Auxiliary battery voltage
Normal condition
1 - 3
No voltage
Continuity
2 - 4
No voltage
No continuity
Voltage (Connect the positive (+) terminal of auxiliary battery to terminal No. 3 and the negative (-) terminal of auxiliary battery to terminal No. 1.)
Continuity (2 Ω or less)