REMOVAL AND INSTALLATION



caution
  • If the electric oil pump is dropped, do not reuse that electric oil pump.
  • Do not operate the electric oil pump when the motor coolant is empty. If the electric oil pump is operated, the electric oil pump service life may be reduced. Therefore, do not reuse that electric oil pump.
Pre-removal and post-installation operation
  • Oil Draining and refilling (Refer to ).
  • Engine Room Under Cover Front A, B Removal and Installation (Refer to GROUP 51 - Under Cover <PHEV>).
  • Front Bumper Assembly Removal and Installation (Refer to GROUP 51 - Front Bumper Assembly ).





Chamber removal steps
<<A>>
>>A<<
1.
EV oil cooler hose connection G (Chamber side)
<<A>>
>>A<<
2.
EV oil cooler hose connection M (Chamber side)

>>B<<
3.
Chamber



EV oil cooler bypass valve and electric oil pump removal steps
<<A>>
>>A<<
2.
EV oil cooler hose M connection (EV oil cooler bypass valve side)
<<A>>
>>A<<
4.
EV oil cooler hose F connection
<<A>>
>>A<<
5.
EV oil cooler hose C connection
<<A>>
>>A<<
6.
EV oil cooler hose B connection
<<A>>
>>A<<
7.
EV oil cooler bypass valve
<<A>>
>>A<<
1.
EV oil cooler hose connection G (Electric oil pump side)


·
Remove the hose clip from EV oil cooler hose A which is assembled into the electric oil pump bracket (Refer to ).
<<A>>
>>A<<
8.
EV oil cooler hose A connection


·
Electric oil pump connector connection


9
.
Electric oil pump & Electric oil pump bracket


10.
Electric oil pump bracket


11
.
Electric oil pump harness bracket


12.
Electric oil pump

REMOVAL SERVICE POINTS



<<A>> EV OIL COOLER HOSE REMOVAL



Make mating marks on the hose and the hose clip as shown to install them in the original position.

INSTALLATION SERVICE POINT



>>A<< EV OIL COOLER HOSE CONNECTION


caution A broken hose clip should not be reused as it will rust.
1.Make mating mark on a new hose clip in the same position as the remove one.

2.Insert the hose until the protrusion of the fitting.
3.Align the mating marks on the hose and hose clip.

>>B<< CHAMBER REMOVAL



Install the chamber bracket, and press its counterhold against the electric oil pump firmly.