REMOVAL AND INSTALLATION <4B1-PHEV>



caution
  • When removing or installing the air flow sensor, be careful not to apply impact to the sensor.
  • Do not reuse the air flow sensor that has been dropped.




Removal steps


·
Air flow sensor connector connection

>>B<<
1.
Air flow sensor


2.
O-ring


3.
Breather hose connection

>>A<<
4.
Air cleaner intake hose


5.
Air cleaner intake duct


6.
Air cleaner assembly (element, cover, body)


7.
Air cleaner cover


8.
Air cleaner element


9.
Air cleaner body


10.
Air cleaner bracket A


11.
Air cleaner bracket B

INSTALLATION SERVICE POINTS



>>A<< AIR CLEANER INTAKE HOSE INSTALLATION




1.Install the hose clamps with the tightening bolt at the position shown in the figure.
2.Check that the tip of tightening bolt does not interfere with the surrounding components.

>>B<< AIR FLOW SENSOR INSTALLATION


1.Install the air flow sensor to the air cleaner cover with care not to damage the O-ring.
2.
caution Do not over-tighten. If the mounting screw is over-tightened, the air cleaner cover can be damaged.
Tighten the mounting screws to the specified torque.