CMU DATA LIST REFERENCE TABLE



note There are 10 CMUs from the CMU 1 to the CMU 5 and the CMU 7 to the CMU 11. The service data of each CMU can be checked.
Item No.
Inspection item
Inspection conditions
Normal value judgement
1
Module voltage
Power supply mode of electric motor switch is ON
Terminal voltage (V) of drive battery module
2
Cell total voltage
Power supply mode of electric motor switch is ON
Sum of voltage (V) of each battery cell composing drive battery module
3
Voltage difference (module - total cell)
Power supply mode of electric motor switch is ON
Difference between sum of battery cell voltage and module voltage
4
Cell 01 voltage
Power supply mode of electric motor switch is ON
Battery cell voltage (V)
5
Cell 02 voltage
Power supply mode of electric motor switch is ON
Battery cell voltage (V)
6
Cell 03 voltage
Power supply mode of electric motor switch is ON
Battery cell voltage (V)
7
Cell 04 voltage
Power supply mode of electric motor switch is ON
Battery cell voltage (V)
8
Cell 05 voltage
Power supply mode of electric motor switch is ON
Battery cell voltage (V)
9
Cell 06 voltage
Power supply mode of electric motor switch is ON
Battery cell voltage (V)
10
Cell 07 voltage
Power supply mode of electric motor switch is ON
Battery cell voltage (V)
11
Cell 08 voltage
Power supply mode of electric motor switch is ON
Battery cell voltage (V)
16
Module temperature 01
Power supply mode of electric motor switch is ON
Battery module temperature (°C)
17
Module temperature 02
Power supply mode of electric motor switch is ON
Battery module temperature (°C)
18
Module temperature 03
Power supply mode of electric motor switch is ON
Battery module temperature (°C)
19
Module temperature 04
Power supply mode of electric motor switch is ON
Battery module temperature (°C)
20
Module temperature 05
Power supply mode of electric motor switch is ON
Battery module temperature (°C)
22
Cell monitor IC 1
Power supply mode of electric motor switch is ON
Normal
23
Cell monitor IC 2
Power supply mode of electric motor switch is ON
Normal
24
Cell monitor IC 3
Power supply mode of electric motor switch is ON
Normal
25
Cell monitor IC 4
Power supply mode of electric motor switch is ON
Normal
26
Cell monitor IC 5
Power supply mode of electric motor switch is ON
Normal
27
Cell monitor IC 6
Power supply mode of electric motor switch is ON
Normal
28
Voltage sensor
Power supply mode of electric motor switch is ON
Normal
29
Microcomputer reference voltage
Power supply mode of electric motor switch is ON
Normal
30
IC reference voltage
Power supply mode of electric motor switch is ON
Normal
31
Temperature sensor 1 (open)
Power supply mode of electric motor switch is ON
Normal
32
Temperature sensor 2 (open)
Power supply mode of electric motor switch is ON
Normal
33
Temperature sensor 3 (open)
Power supply mode of electric motor switch is ON
Normal
34
Temperature sensor 4 (open)
Power supply mode of electric motor switch is ON
Normal
35
Temperature sensor 5 (open)
Power supply mode of electric motor switch is ON
Normal
37
Temperature sensor 1 (short)
Power supply mode of electric motor switch is ON
Normal
38
Temperature sensor 2 (short)
Power supply mode of electric motor switch is ON
Normal
39
Temperature sensor 3 (short)
Power supply mode of electric motor switch is ON
Normal
40
Temperature sensor 4 (short)
Power supply mode of electric motor switch is ON
Normal
41
Temperature sensor 5 (short)
Power supply mode of electric motor switch is ON
Normal
43
Cell 01 voltage underflow
Power supply mode of electric motor switch is ON
Normal
44
Cell 02 voltage underflow
Power supply mode of electric motor switch is ON
Normal
45
Cell 03 voltage underflow
Power supply mode of electric motor switch is ON
Normal
46
Cell 04 voltage underflow
Power supply mode of electric motor switch is ON
Normal
47
Cell 05 voltage underflow
Power supply mode of electric motor switch is ON
Normal
48
Cell 06 voltage underflow
Power supply mode of electric motor switch is ON
Normal
49
Cell 07 voltage underflow
Power supply mode of electric motor switch is ON
Normal
50
Cell 08 voltage underflow
Power supply mode of electric motor switch is ON
Normal
55
Cell 01 voltage overflow
Power supply mode of electric motor switch is ON
Normal
56
Cell 02 voltage overflow
Power supply mode of electric motor switch is ON
Normal
57
Cell 03 voltage overflow
Power supply mode of electric motor switch is ON
Normal
58
Cell 04 voltage overflow
Power supply mode of electric motor switch is ON
Normal
59
Cell 05 voltage overflow
Power supply mode of electric motor switch is ON
Normal
60
Cell 06 voltage overflow
Power supply mode of electric motor switch is ON
Normal
61
Cell 07 voltage overflow
Power supply mode of electric motor switch is ON
Normal
62
Cell 08 voltage overflow
Power supply mode of electric motor switch is ON
Normal
67
Temperature sensor 1 underflow
Power supply mode of electric motor switch is ON
Normal
68
Temperature sensor 2 underflow
Power supply mode of electric motor switch is ON
Normal
69
Temperature sensor 3 underflow
Power supply mode of electric motor switch is ON
Normal
70
Temperature sensor 4 underflow
Power supply mode of electric motor switch is ON
Normal
71
Temperature sensor 5 underflow
Power supply mode of electric motor switch is ON
Normal
73
Temperature sensor 1 overflow
Power supply mode of electric motor switch is ON
Normal
74
Temperature sensor 2 overflow
Power supply mode of electric motor switch is ON
Normal
75
Temperature sensor 3 overflow
Power supply mode of electric motor switch is ON
Normal
76
Temperature sensor 4 overflow
Power supply mode of electric motor switch is ON
Normal
77
Temperature sensor 5 overflow
Power supply mode of electric motor switch is ON
Normal
79
EEPROM Fail (numbering data read)
Power supply mode of electric motor switch is ON
Normal
80
EEPROM Fail (learning data read)
Power supply mode of electric motor switch is ON
Normal
81
CAN controller
Power supply mode of electric motor switch is ON
Normal
82
Cell 01 connection terminal
Power supply mode of electric motor switch is ON
Normal
83
Cell 03 connection terminal
Power supply mode of electric motor switch is ON
Normal
84
Cell 05 connection terminal
Power supply mode of electric motor switch is ON
Normal
85
Cell 07 connection terminal
Power supply mode of electric motor switch is ON
Normal
88
A/D conversion (reference voltage)
Power supply mode of electric motor switch is ON
Normal
89
A/D conversion (temperature sensor 1)
Power supply mode of electric motor switch is ON
Normal
90
A/D conversion (temperature sensor 2)
Power supply mode of electric motor switch is ON
Normal
91
A/D conversion (temperature sensor 3)
Power supply mode of electric motor switch is ON
Normal
92
A/D conversion (temperature sensor 4)
Power supply mode of electric motor switch is ON
Normal
93
A/D conversion (temperature sensor 5)
Power supply mode of electric motor switch is ON
Normal
95
A/D conversion (module voltage)
Power supply mode of electric motor switch is ON
Normal
96
Balancer drive time fail (20h)
Power supply mode of electric motor switch is ON
Normal
96
EEPROM Fail (failure information read)
Power supply mode of electric motor switch is ON
Normal
98
Bat-CAN (bus off)
Power supply mode of electric motor switch is ON
Normal