DRIVE BATTERY REAR CABLE (P, N LINE) QUICK CHARGING RELAY CONTINUTY CHECK


caution Before measuring the insulation resistance, set the range of the electric insulation tester (special tool: MB992355) to 250 V. If a range exceeding 250 V is used for the measurement, the part may be damaged.


1.Use the electric insulation tester (special tool: MB992355) and set it to the 250 V range.
2.Measure the insulation resistance between the inner cable mounting bolt hole and the outer cable mounting bolt hole on the drive battery rear cable (P, N line) as shown.
Standard value: 10 MΩ or more
3.If not within the standard value, replace the drive battery rear cable(P, N line).