Code No. P1D34: Input Current Sensor Fail,
Code No. P1D35: Output Current Sensor Fail




TROUBLE JUDGEMENT


Check Conditions
  • When the charging cable is connected.
Judgement Criterion
    <Code No. P1D34>

    • The input current sensor is abnormal.
    <Code No. P1D35>

    • The output current sensor is abnormal.

FAIL-SAFE AND BACKUP FUNCTION



  • The charge is stopped.

PROBABLE CAUSE



  • The on board charger/DC-DC converter is failed.

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III diagnosis code


Q. Is the diagnosis code stored?

Replace the on board charger/DC-DC converter.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).