CONNECTOR INSPECTION SERVICE POINTS




VISUAL INSPECTION




  • Connector is disconnected or improperly connected
  • Connector pins are pulled out
  • Due to harness tension at terminal section
  • Low contact pressure between male and female terminals
  • Low connection pressure due to rusted terminals or foreign matter lodged in terminals

CONNECTOR PIN INSPECTION



If the connector pin stopper is damaged, the terminal connections (male and female pins) will not be perfect even if the connector body is connected, and the pins may pull out of the reverse side of the connector. Therefore, gently pull the harnesses one by one to make sure that no pins pull out of the connector.

CONNECTOR ENGAGEMENT INSPECTION



Use special tool inspection harness (MB991219) (connector pin connection pressure inspection harness of the inspection harness set) to inspect the engagement of the male pins and female pins. (Pin drawing force: 1 N or more)