
|
1.Disconnect the oil feeder control valve connector.
| caution |
To prevent the coil from burning, keep the duration of the
voltage application as short as possible.
|
2.Make sure that the oil feeder control valve generates a tick sound when the battery
voltage is applied between the connector terminals at the oil feeder control valve side.
|
|
|
1.Disconnect the oil feeder control valve connector.
|
|
|
2.Measure the resistance between the terminals of the connector at the oil feeder control
valve.
|
|
|
Standard value: 6.9 -
7.9 Ω
(at 20°C)
|
|
|
3.If resistance is outside the standard value, replace the oil feeder control valve.
|