INSPECTION PROCEDURE A-2: Central door locking system does not operate even when door lock switch of power window main switch operated.
| caution | Before replacing the ECU, ensure that the power supply circuit, the earth circuit and the communication circuit are normal. |
OPERATION
COMMENTS ON TROUBLE SYMPTOM
PROBABLE CAUSES
- Malfunction of the door lock switch (built in the power window main switch)
- Malfunction of ETACS-ECU
- Damaged wiring harness and connectors
DIAGNOSTIC PROCEDURE |
STEP 1. Central door locking system operation check |
| Check that the central door locking system works normally. |
Q.
Is the check result normal?
|
Go to Step 2. |
|
Refer to Inspection Procedure 1 "Central door locking system does not work at all ." |
|
STEP 2. Connector check: F-13 power window main switch connector |
Q.
Is the check result normal?
|
Go to Step 3. |
|
Repair the defective connector. |
|
STEP 3. Central door lock switch check (built in the power window main switch) |
Check that the central door lock switch works normally (Refer to Central Door Lock Switch Check ). |
Q.
Is the check result normal?
|
Go to Step 4. |
|
Replace the power window main switch. |
|
STEP 4. Connector check: C-411, C-415 ETACS-ECU connector |
Q.
Is the check result normal?
|
Go to Step 5. |
|
Repair the defective connector. |
|
STEP 5. Check of the wiring harness between the C-411 ETACS-ECU connector terminal No. 2 and the F-13 power window main switch connector terminal No. 14, the C-415 ETACS-ECU connector terminal No. 15 and the F-13 power window main switch connector terminal No. 13 |
|
|
Q.
Is the check result normal?
|
YES : Go to Step 6. |
|
Repair the wiring harness. |
|
STEP 6. Retest the system. |
| Check that the central door locking system works normally. |
Q.
Is the check result normal?
|
| YES : No action is necessary and testing is complete. |
|
Replace ETACS-ECU. |
|

Refer to Inspection Procedure 1 "Central door locking system does not work at all 