Inspection Procedure 9: The multi information display screen cannot be changed with the operation of the meter information switch.



caution Before replacing the combination meter, be sure to check that the power supply circuit, earth circuit, and communication circuit are normal.

COMMENTS ON TROUBLE SYMPTOM




PROBABLE CAUSES



  • Malfunction of meter information switch
  • Malfunction of combination meter
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III diagnosis code



Q. Is the diagnosis code set?





STEP 2. Connector check: C-34 meter information switch connector


Q. Is the check result normal?





STEP 3. Meter information switch check



Q. Is the check result normal?





STEP 4. Resistance measurement at the C-34 meter information switch connector


(1)Disconnect the meter information switch connector, and then measure at the wiring harness side.
(2)Measure the resistance from C-34 meter information switch connector terminal No. 4 to body earth.
OK: Continuity exists (2 Ω or less)

Q. Is the check result normal?





STEP 5. Check the wiring harness between the C-34 meter information switch connector terminal No. 4 and the C-01 earth joint connector terminal No. 11.



note Before the wiring harness check, check the joint connector C-108, and repair them if necessary.

Q. Is the check result normal?





STEP 6. Connector check: C-203 combination meter connector


Q. Is the check result normal?





STEP 7. Check the wiring harness between the C-203 combination meter connector terminal No. 3 and the C-34 meter information switch terminal No. 1.



Q. Is the check result normal?





STEP 8. Retest the system



Q. Is the check result normal?