Inspection Procedure 5: DIAGNOSIS MODE cannot be made an entry. Mobile Phone item is not displayed on the MENU screen of audio. <Vehicles with MMCS>
| caution | Before replacing the hands
free-ECU or multivision display, ensure that the power supply circuit, the earth circuit and
the communication circuit are normal. |
COMMENTS ON TROUBLE SYMPTOM
PROBABLE CAUSES
- The hands free-ECU may be defective.
- The multivision display may be defective.
- Damaged harness wires and connectors
DIAGNOSIS PROCEDURE |
STEP 1. Check the multivision display operation. |
| Check if the multivision display work normally and the sound is output. |
Q.
Is the check result normal?
|
Go to Step 2 |
|
Troubleshoot the multivision display. (Refer to .) |
|
STEP 2. Connector check: C-218 hands free ECU connector, C-106 multivision display connector |
Q.
Is the check result normal?
|
Go to Step 3. |
|
Repair the defective connector. |
|
STEP 3. Check the wiring harness between C-218 hands free ECU connector terminal No.2, 16 and C-106 multivision display connector terminal No.9, 18. |
|
|
Q.
Is the check result normal?
|
Go to Step 4. |
|
Repair the wiring harness. |
|
STEP 4. Check if the power supply circuit of hands free-ECU have a problem. |
Q.
Is the check result normal?
|
Go to Step 5 |
|
Repair according to the troubleshooting for reference. |
|
STEP 5. Replace the hands free-ECU temporarily, and check the trouble symptom. |
Q.
Is the check result normal?
|
Replace the hands free-ECU. |
|
Replace the multivision display. |
|

Troubleshoot the multivision display. (Refer to 