Inspection Procedure 1: The daytime running lamps do not illuminate normally.



caution Whenever the ECU is replaced, ensure that the power supply circuit, the earth circuit and the communication circuit are normal.

COMMENTS ON TROUBLE SYMPTOM




PROBABLE CAUSES



  • Malfunction of the ETACS-ECU
  • Malfunction of the daytime running lamp relay
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III diagnosis code.



Q. Is the diagnosis code set?





STEP 2. M.U.T.-III data list




  • Turn the ignition switch to the "ON" position.
Item No.
Item name
Normal condition
30
Ignition switch(IG1)
ON
OK: Normal condition is displayed.

Q. Is the check result normal?





STEP 3. Connector check: A-27X daytime running lamp relay connector, C-410 ETACS-ECU connector


Q. Is the check result normal?





STEP 4. Check the daytime running lamp relay


Q. Is the check result normal?





STEP 5. Voltage measurement at the A-27X daytime running lamp relay connector


(1)Remove the daytime running lamp relay, and measure at the relay box side.
(2)Measure the voltage between terminal 1 and the body earth, and between terminal 4 and body earth.
OK: System voltage

Q. Is the check result normal?





STEP 6. Wiring harness check between the A-27X daytime running lamp relay connector terminal No. 1/4 and the fusible link (36) <petrol> or (38) <diesel>



  • Check the output lines for open circuit.

Q. Is the check result normal?





STEP 7. Wiring harness check between the A-27X daytime running lamp relay connector terminal No. 2 and the C-410 ETACS-ECU connector terminal No. 10



  • Check the output lines for open circuit.

Q. Is the check result normal?





STEP 8. Wiring harness check between the A-27X daytime running lamp relay connector terminal No. 3 and the A-52 intermediate connector terminal No. 2



  • Check the output lines for open circuit.

Q. Is the check result normal?





STEP 9. Wiring harness check between the A-52 intermediate connector terminal No. 4 and the body earth


note Before the wiring harness check, check the intermediate connector C-15, and then repair that if necessary.

  • Check the earth lines for open circuit.

Q. Is the check result normal?





STEP 10. Retest the system.



Q. Is the check result normal?