GENERAL INFORMATION






note For the control of Auto Stop & Go (AS&G) System, refer to GROUP 17 - Auto Stop & Go (AS&G) System .

General operation of DC/DC converter



IGNITION SWITCH:OFF






IGNITION SWITCH: ON or ACC position <except at auto start by Auto Stop & Go (AS&G) system>






IGNITION SWITCH: ON position <at auto start by Auto Stop & Go (AS&G) System>





note DC/DC converter boost stop condition (boost is stopped when any of the following applies)
  • Input voltage to DC/DC converter is 12.2 V or more.
  • DC/DC converter boost duration is 5 seconds or more.
  • Diagnosis code B1302 or B1301 is set in AS&G-ECU. For the setting condition of diagnosis code B1301 and B1302, refer to GROUP 17 - Auto Stop & Go (AS&G) System, Troubleshooting .