INSPECTION PROCEDURE 11: A/C pressure sensor system




COMMENTS ON TROUBLE SYMPTOM


If the A/C pressure sensor system is defective, the wiring harness between the A/C pressure sensor and the A/C control panel is suspected.

PROBABLE CAUSES



  • Malfunction of the A/C pressure sensor
  • Malfunction of the A/C control panel
  • Wiring harness or connector failure

DIAGNOSTIC PROCEDURE


STEP 1. Connector check: A-63 A/C pressure sensor connector


Q. Is the check result normal?

Go to Step 2.
Repair the connector concerned.

STEP 2. Inspection of the A/C pressure sensor


Refer to .

Q. Is the A/C pressure sensor normal?

Go to Step 3.
Replace the A/C pressure sensor.

STEP 3. Connector check: C-216 A/C control panel connector


Q. Is the check result normal?

Go to Step 4.
Repair the connector concerned.

STEP 4. Check the wiring harness wires between A-63 A/C pressure sensor connector (terminals 3, 2 and 1) and C-216 A/C control panel connector (terminals 12, 11 and 6).



  • Check the input line for open circuit.
note Prior to the wiring harness inspection, check intermediate connector C-128, and repair if necessary.

Q. Is the check result normal?

Go to Step 5.
Repair the wiring harness.

STEP 5. Retest the system.


Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).
Replace the A/C control panel.