Q.
Is diagnosis code set?
|
|
|
Carry out the diagnosis for the set code. (Refer to )
Then go to Step 4.
|
|
|
|
|
|
- Check the SRS warning lamp output lines for open circuit.
|
|
|
Q.
Is the check result normal?
|
|
|
Repair the harness wires. Then go to Step 4.
|
|
|
|
|
|
(1)Check that the negative auxiliary battery terminal is disconnected. If the negative
auxiliary battery terminal is connected, disconnect it.
|
|
|
(2)Disconnected the B-112 SRS-ECU connector.
|
|
|
(3)Connect the negative auxiliary battery terminal.
|
|
|
(4)Electric motor switch to the "ON" position.
|
|
|
(5)
| caution |
Do not insert a test probe into the
terminal from its front side directly, as the connector contact pressure may be weakened.
|
Check that SRS warning lamp turn "ON" when SRS-ECU connector B-112 is disconnected. Check
that the same warning lamp turn "OFF" when the terminal No.39 of the above connector is earthed.
|
|
|
Q.
Is the check result normal?
|
|
|
Replace the combination meter (Refer to GROUP 54A, Combination Meter ).
|
|
|
|
|
|
Q.
Is diagnosis code B1551 set?
|
|
|
Replace the SRS-ECU (Refer to ).
|
|
|
|
|
|
An intermittent malfunction is suspected (Refer to GROUP 00, How to Cope with
Intermittent Malfunction ).
|
|
|
|