Check if the diagnosis code No. P0ABA for other systems is set to the MCU.
|
|
Q.
Is the diagnosis code set?
|
|
Carry out troubleshooting for the diagnosis code No. P0ABA. (Refer to .)
|
|
|
|
Check if the diagnosis code is set to the EV-ECU.
|
|
Q.
Is the diagnosis code set?
|
|
Carry out troubleshooting for the EV-ECU. (Refer to .)
Then go to Step 3.
|
|
|
|
Check the battery level status with the main battery level indicator in the combination
meter.
|
|
Q.
Is the check result normal?
|
|
Charge the main battery. Then go to Step 5.
|
|
|
|
Check the charging rate of the main battery in the BMU service data (refer to ).
|
|
Data list
- Item No. 1 : State of charge (for control)
|
|
Q.
Is the check result normal?
|
|
Charge the main battery. Then go to Step 5.
|
|
|
|
Check again if the diagnosis code is set to the MCU.
|
|
(1)Erase the stored diagnosis code.
|
|
(2)Set the electric motor switch from the LOCK (OFF) position to the ON position.
|
|
(3)Set the electric motor switch to the LOCK (OFF) position, and start the electric
motor unit.
|
|
(5)Check if the diagnosis code is set.
|
|
Q.
Is the diagnosis code set?
|
|
The diagnosis is complete.
|
|
|