Use the M.U.T.-III to diagnose the CAN bus lines.
|
|
|
Q.
Is the check result normal?
|
|
|
Repair the CAN bus line. (Refer to GROUP 54C - Troubleshooting .) Then go to Step 2.
|
|
|
|
|
|
Check again if the diagnosis code No. U1108 is set to the MCU.
|
|
|
(1)Erase the stored diagnosis code.
|
|
|
(2)Set the electric motor switch from the LOCK (OFF) position to the ON position.
|
|
|
(3)Check if the diagnosis code is set.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
This diagnosis is complete.
|
|
|
|
|
|
Check if the combination meter-related diagnosis code is set.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Carry out troubleshooting for the combination meter. (Refer to GROUP 54A - Troubleshooting ).
|
|
|
|
|
|
Check if the diagnosis code No. U1108 is set to the ETACS-ECU.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Check again if the diagnosis code is set to the MCU.
|
|
|
(1)Erase the stored diagnosis code.
|
|
|
(2)Set the electric motor switch from the LOCK (OFF) position to the ON position.
|
|
|
(3)Check if the diagnosis code is set.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Replace the combination meter.
|
|
|
|
|
|
A poor connection, open circuit of the wiring harness or other intermittent malfunction is present in the CAN bus line between the combination meter and MCU (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points, How to Handle Intermittent Malfunction )
|
|
|
|
|
|
Check again if the diagnosis code is set to the MCU.
|
|
|
(1)Erase the stored diagnosis code.
|
|
|
(2)Set the electric motor switch from the LOCK (OFF) position to the ON position.
|
|
|
(3)Check if the diagnosis code is set.
|
|
|
Q.
Is the diagnosis code set?
|
|
|
A poor connection, open circuit of the wiring harness or other intermittent malfunction is present in the CAN bus line between the combination meter and MCU (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points, How to Handle Intermittent Malfunction )
|
|
|
|