Check Conditions
- The main battery cooling fan relay is turned ON.
- The following diagnosis codes are not set.
- P1A47: Power supply of main battery cooling fan relay abnormal
(short circuits to power supply system, open circuits)
- P1A4E: Power supply of main battery cooling fan relay abnormal (short circuits to
earth system)
|
|
|
Judgement Criterion
- The PWM output signal of the main battery cooling fan is 100 % (while the
fan is stopped) and the PWM output signal status of the main battery cooling fan is High (during
the rotation).
|
|
|
- The main battery cooling fan is failed.
- Short circuits to power supply system of main battery cooling fan circuit; poor
contact of connector.
- The BMU is failed.
|
|
|
Q.
Is the check result normal?
|
|
|
- Disconnect the connector and measure the voltage at the female
side.
- Electric motor switch: ON
- Voltage between terminal No. 2 and earth.
|
|
|
Q.
Is the check result normal?
|
|
|
Q.
Is the check result normal?
|
|
|
- Check output line for short circuit to power supply.
|
|
|
Q.
Is the check result normal?
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|
|
|
Q.
Is the diagnosis code set?
|
|
|
Replace the main battery.
|
|
|
|
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|