Check Conditions
- 3 seconds elapse after the electric motor switch is turned ON, or 3 seconds elapse
after the main battery starts to be charged.
- The absolute value of the current is less than 1 A.
- The energy level gauge is more than 4 segments.
- None of the following diagnosis codes occur at the same time.
- P1AA8: Local CAN (for main battery) signal time-out
- U1082: Local CAN (for main battery) bus off
|
|
|
Judgement Criterion
- When the information that the difference is more than 0.2 V between the lowest battery
cell voltage and the highest battery cell voltage is received for more than 5 seconds.
|
|
|
- The module (battery cell and CMU) in the main battery
is failed.
|
|
|
- Item 33: largest difference between cell voltage
|
|
|
OK: 0.2 V less (electric motor switch: ON, also the energy level gauge of the combination
meter has more than 4 segments.)
|
|
|
Q.
Is the check result normal?
|
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|
|
|
Replace the main battery.
|
|
|
|