SOLENOID VALVE CHECK
| 1.Use the M.U.T.-III to measure the A/T fluid temperature and check that the A/T fluid temperature is 20°C. |
![]() |
7.Disconnect the solenoid valve connectors. |
![]() |
8.Measure the resistance between terminals 1 and 2 at each solenoid valve side. Standard value: 2.7 - 3.4 Ω (A/T fluid temperature 20°C) 9.If not within the standard value, replace the solenoid valve. 10.If within the standard value, check the harness wire between A/T control solenoid valve assembly connector and each solenoid valve connector. If a problem is not found at the steps above, check the solenoid valve O-rings and replace if necessary. |