Code No.2004: P/W (AS) Sensor fail (ground) <LH drive vehicles>
|

COMMENTS ON TROUBLE SYMPTOM
Current trouble
- If the front power window motor (RH) is operated while short to earth is detected
in the power supply of the front power window motor (RH) sensor, ETACS-ECU sets the diagnosis
code No. 2004.
- If the diagnosis code No. 2004 is set as past trouble, carry out diagnosis with
particular emphasis on wiring and connector(s) in the CAN bus line. For diagnosis procedures,
refer to How to cope with past trouble (Refer to GROUP 00, How to Use Troubleshooting/Inspection Service
Points - How to Treat Past Trouble
).
PROBABLE CAUSES
- Malfunction of the front power window motor (RH)
- Malfunction of the front power window sub switch
- Damaged harness wires and connectors
DIAGNOSIS PROCEDURE |
STEP 1. Connector check: E-26 front power window sub switch connector and E-01 front power window motor (RH) connector |
![]() |
Q.
Is the check result normal? Go to Step 2. Repair the connector. |
STEP 2. Check the wiring harness between E-26 front power window sub switch connector terminal No. 3 to E-01 front power window motor (RH) connector terminal No. 5. |
![]() |
Q.
Is the check result normal? Go to Step 3. Repair the wiring harness. |
STEP 3. Check whether the diagnosis code is reset. |
| (1)Replace the front power window motor (RH). |
| (2)Check that diagnosis code is not reset. |
Q.
Is diagnosis code set?
|
Replace the front power window sub switch. |
|
The procedure is complete. |
|


Repair the connector.