Inspection Procedure 3: The blower air volume cannot be changed






COMMENTS ON TROUBLE SYMPTOM




PROBABLE CAUSES



  • Malfunction of the A/C temperature control resistor
  • Damaged the wiring harness or connectors
  • Malfunction of the blower switch

DIAGNOSIS PROCEDURE


STEP 1. Check that the blower motor operates when the blower switch is moved to the "4 (HI)" position.


(1)Turn the ignition switch to the "ON" position.
(2)Turn the blower switch to the "4 (HI) " position.

Q. Does the blower motor operate when the blower switch is moved to the "4 (HI)" position?

Go to Step 2.
Refer to Inspection procedure 2 "The blower does not work ."

STEP 2. Connector check: C-06 blower switch connector




Q. Is the check result normal?

Go to Step 3.

Repair the connector.

STEP 3. Check the blower switch continuity.


Refer to .

Q. Is the blower switch continuity in good condition?

Go to Step 4.
Replace the blower switch.

STEP 4. Connector check: C-23 A/C temperature control resistor connector




Q. Is the check result normal?

Go to Step 5.

Repair the connector.

STEP 5. Check the A/C temperature control resistor resistance value.


Refer to .

Q. Is the measured value at the standard value?

Go to Step 6.
Replace the A/C temperature control resistor.

STEP 6. Check the wiring harness between C-06 blower switch connector (terminals 2, 1 and 4) and C-23 A/C temperature control resistor connector (terminals 4, 3 and 2).





  • Check the blower switch output line for open circuit.

Q. Is the check result normal?

Go to Step 7.

Repair the wiring harness.

STEP 7. Connector check: C-28 blower motor connector




Q. Is the check result normal?

Go to Step 8.

Repair the connector.

STEP 8. Check the wiring harness between C-28 blower motor connector terminal No.1 and C-23 A/C temperature control resistor connector terminal No.1.







  • Check the blower motor power supply line for open circuit.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00, How to Cope with Intermittent Malfunction ).

Repair the wiring harness.