Inspection Procedure 4: Starting Impossible (No Initial Combustion) <M/T>






COMMENT ON TROUBLE SYMPTOM



  • Failure is possibly caused by failed starter itself or failed related circuit.

PROBABLE CAUSES



  • Failed battery
  • Failed starter motor
  • Failed starter relay
  • Open/short circuit in starter associated circuit or loose connector contact
  • Failed engine-ECU

DIAGNOSIS PROCEDURE


STEP 1. Check battery voltage.



  • Measure battery voltage at cranking.
OK: 8 V or higher

Q. Is the check result normal?

Go to Step 2.
Check battery (Refer to GROUP 54A - Battery - On-vehicle Service - Battery Test ).

STEP 2. M.U.T.-III data list



  • Item 40: Starter switch
OK:
    ON (Ignition switch: ST)
    OFF (Ignition switch: ON)

Q. Is the check result normal?

Go to Step 13.
Go to Step 3.

STEP 3. Connector check: A-16X starter relay connector



Q. Is the check result normal?

Go to Step 4.

Repair or replace.

STEP 4. Check starter relay.



  • Check starter relay (Refer to GROUP 16 - Starting System - Starter Relay Check )

Q. Is the check result normal?

Go to Step 5.
Replace the starter relay.

STEP 5. Perform voltage measurement at A-16X starter relay connector.




  • Disconnect connector, and measure at the harness side.
  • Ignition switch: ST
  • Voltage between terminal No. 2 and earth.
OK: System voltage

Q. Is the check result normal?

Go to Step 8.

Go to Step 6.

STEP 6. Connector check: C-307 ignition switch connector



Q. Is the check result normal?

Go to Step 7.

Repair or replace.

STEP 7. Check ignition switch.





  • Check ignition switch (Refer to GROUP 54A - Ignition Switch - Inspection ).

Q. Is the check result normal?


    Check intermediate connectors A-115, C-207 and C-211, and repair if necessary. If intermediate connectors are normal, check and repair harness between A-16X (terminal No. 2) starter relay connector and C-307 (terminal No. 5) ignition switch connector.

    • Check power supply line for open/short circuit.

Replace the ignition switch.

STEP 8. Perform voltage measurement at A-16X starter relay connector.




  • Disconnect connector, and measure at the harness side.
  • Voltage between terminal No. 4 and earth.
OK: System voltage

Q. Is the check result normal?


    Go to Step 9.


    Check and repair harness between A16X (terminal No. 4) starter relay connector and battery.

    • Check power supply line for open/short circuit.

STEP 9. Perform resistance measurement at A-16X starter relay connector.




  • Disconnect connector, and measure at harness side.
  • Resistance between terminal No. 1 and earth.
OK: Continuity (2Ω or less)

Q. Is the check result normal?

Go to Step 10.


    Check and repair harness between A16X (terminal No. 1) starter relay connector and body earth.

    • Check earth line for open circuit and damage.

STEP 10. Connector check: A-110 starter connector



Q. Is the check result normal?

Go to Step 11.

Repair or replace.

STEP 11. Check harness between A-110 (terminal No. 1) starter connector and A-16X (terminal No. 3) starter relay connector.




note Before checking harness, check intermediate connector A-27, and repair if necessary.

  • Check output line for open/short circuit.

Q. Is the check result normal?

Go to Step 12.

Repair the damaged harness wire.

STEP 12. Connector check: C-103 engine-ECU connector




Q. Is the check result normal?


    Check intermediate connector A-115, and repair if necessary. If intermediate connector is normal, check and repair harness between C-103 (terminal No. 111) starter connector and A-16X (terminal No. 3) starter relay connector.

    • Check output line for short circuit.

Repair or replace.

STEP 13. Connector check: A-110 starter connector



Q. Is the check result normal?


    Go to Step 14.

Repair or replace.

STEP 14. Perform voltage measurement at A-110 starter connector.




  • Disconnect connector, and measure at the harness side.
  • Ignition switch: ST
  • Voltage between terminal No. 1 and earth.
OK: System voltage

Q. Is the check result normal?

Go to Step 16.

Go to Step 15.

STEP 15. Connector check: A-16X starter relay connector




Q. Is the check result normal?


    Check intermediate connector A-27, and repair if necessary. If intermediate connector is normal, check and repair harness between A-16X (terminal No. 3) starter relay connector and A-110 (terminal No. 1) starter connector.

    • Check output line for open circuit and damage.

Repair or replace.

STEP 16. Connector check: A-10 starter connector



Q. Is the check result normal?


    Go to Step 17.

Repair or replace.

STEP 17. Perform voltage measurement at A-10 starter connector.




  • Disconnect connector, and measure at the harness side.
  • Voltage between terminal No. 1 and earth.
OK: System voltage

Q. Is the check result normal?


    Go to Step 18.


    Check and repair harness between A-10 (terminal No. 1) starter connector and battery.

    • Check power supply line for open/short circuit.

STEP 18. Connector check: A-16X starter relay connector and C-307 Ignition switch connector




Q. Are the check results normal?

Go to Step 19.

Repair or replace.

STEP 19. Check harness between C-307 (terminal No. 5) ignition switch connector and A-16X (terminal No. 2) starter relay connector.




note Before checking harness, check intermediate connectors A-115, C-207 and C-211, and repair if necessary.

  • Check output line for damage.

Q. Is the check result normal?

Go to Step 20.

Repair the damaged harness wire.

STEP 20. Check harness between A-16X (terminal No. 4) starter relay connector and battery




  • Check power supply line for damage.

Q. Is the check result normal?

Go to Step 21.

Repair the damaged harness wire.

STEP 21. Check harness between A-16X (terminal No. 3) starter relay connector and A-110 (terminal No. 1) starter relay connector




note Before checking harness, check intermediate connector A-27, and repair if necessary.

  • Check output line for damage.

Q. Is the check result normal?

Go to Step 22.

Repair the damaged harness wire.

STEP 22. Check harness between A-10 (terminal No. 1) starter connector and battery.




  • Check power supply line for damage.

Q. Is the check result normal?

Replace the starter.

Repair the damaged harness wire.