If only the fuel gauge does not operate, the fuel gauge unit, the combination meter, wiring
harness or connector(s) may be defective.
|
|
|
- Damaged harness wires and connectors
- Malfunction of the fuel gauge unit
- Malfunction of combination meter
|

|
(1)Disconnect F-09 fuel gauge unit connector.
|

|
(2)Connect a test lamp (12 V - 3.4 W) via special tool test harness (MB991219) between
the wiring harness connector terminals 1 and 2. (3)Turn the ignition switch to the "ON" position.
Q.
Does the test lamp illuminate?
Go to Step 7.
Go to Step 2.
|



|
Q.
Is combination meter connector C-113 and fuel gauge unit connector F-09 in good condition?
Go to Step 3.
Repair or replace the damaged component(s).
|
|
|
Check the input lines for open circuit and short circuit.
|

|
| note |
Prior to the wiring harness inspection, check intermediate connector C-30 and repair if
necessary.
|
Q.
Is the wiring harness between combination meter connector C-113 (terminal 22) and
fuel gauge unit connector F-09 (terminal 1) in good condition?
Go to Step 4.
Repair or replace the damaged component(s). Then go to Step 4.
|
|
|
Q.
Is the fuel gauge normal?
|
|
|
The procedure is complete. (If no malfunctions are found in all steps, an intermittent
malfunction is suspected. Refer to GROUP 00 / How to Cope with Intermittent Malfunction ).
|
|
|
|
|
|
Check the earth wires for open circuit.
|

|
Q.
Is the wiring harness between fuel gauge unit connector F-09 (terminal 2) and earth
in good condition?
Go to Step 6.
Repair or replace the damaged component(s).
|
|
|
Q.
Is the fuel gauge normal?
|
|
|
The procedure is complete. (If no malfunctions are found in all steps, an intermittent
malfunction is suspected. Refer to GROUP 00 / How to Cope with Intermittent Malfunction ).
|
|
|
|
|
|
Carry out the troubleshooting again.
|
|
|
|
|
|
Q.
Is the fuel gauge normal?
|
|
|
Replace the fuel gauge unit.
|
|
|
|
|
|
Q.
Is the fuel gauge normal?
|
|
|
The procedure is complete. (If no malfunctions are found in all steps, an intermittent
malfunction is suspected. Refer to GROUP 00 / How to Cope with Intermittent Malfunction ).
|
|
|
|
|
|
Replace combination meter.
|
|
|
|