If only the engine coolant temperature gauge does not operate, the engine ECU system,
the combination meter, the wiring harness or its connector may be defective.
|
|
|
- Damaged harness wires and connectors
- Malfunction of the engine coolant temperature gauge unit
- Malfunction of combination meter
|

|
(1)Disconnect the A-108 engine coolant temperature gauge unit connector.
|

|
(2)Connect a test lamp (12 V - 3.4 W to 12 V - 7.0 W) to the wiring harness
side connector. (3)Ignition switch: ON
Q.
Does the test lamp illuminate?
Go to Step 5.
Go to Step 2.
|



|
Q.
Is combination meter connector C-113 and engine coolant temperature gauge unit connector
A-108 in good condition?
Go to Step 3.
Repair or replace the damage component(s).
|
|
|
Q.
Is the engine coolant temperature gauge normal?
|
|
|
The procedure is complete. (If no malfunctions are found in all steps, an intermittent
malfunction is suspected. Refer to GROUP 00 / How to Cope with Intermittent Malfunction ).
|
|
|
|



|
Check the input lines for open circuit and short circuit.
|


|
| note |
Prior to the wiring harness inspection, check intermediate connector C-53 <LHD> or
C-35 <RHD>, and repair if necessary.
|
Q.
Is the wiring harness between combination meter connector C-113 (terminal 21) and
engine coolant temperature gauge unit connector A-108 (terminal 1) in good condition?
Go to Step 6.
Repair or replace the damage component(s).
|
|
|
Q.
Is the engine coolant temperature gauge unit normal?
|
|
|
Replace the engine coolant temperature gauge unit.
|
|
|
|
|
|
Q.
Is the engine coolant temperature gauge normal?
|
|
|
The procedure is complete. (If no malfunctions are found in all steps, an intermittent
malfunction is suspected. Refer to GROUP 00 / How to Cope with Intermittent Malfunction ).
|
|
|
|
|
|
Replace the combination meter.
|
|
|
|