Code No. P2A00: Air/Fuel Ratio Sensor (Lambda Sensor) Performance
DIAGNOSIS CONTENT
TROUBLE JUDGMENT
Check Conditions
- Oxygen concentration is normal.
- Diagnosis released.
- Influence of injection quantity on the air/fuel ratio sensor (Lambda sensor) is
unique.
- The oxygen concentration measured in thrust is above the sum of the calculated oxygen concentration
and tolerance band.
DIAGNOSIS CONTENT
TROUBLE JUDGMENT
Check Conditions
- Oxygen concentration is normal.
- Diagnosis released.
- Influence of injection quantity on the air/fuel ratio sensor (Lambda sensor) is
unique.
- The oxygen concentration measured in thrust is below the difference of the calculated
oxygen concentration and negative tolerance band.
PROBABLE CAUSE
- Failed air/fuel ratio sensor (Lambda sensor)
- Failed electrical harness in air/fuel ratio sensor (Lambda sensor) circuit