Code No. P2002: DPF Flow Resistance Below Limit




DIAGNOSIS CONTENT




TROUBLE JUDGMENT


Check Conditions
  • The engine is running.
  • Examination of flow resistance has not been inhibited.


  • Calculated exhaust gas flow in the particulate filter is above the threshold.


  • The loading simulation is switched off.

    Judgment Criteria
    Case 1
    • The differential pressure is below the output of the curve while the exhaust gas flow rate is above the threshold.
    • Regeneration is not active.
    Case 2
    • The filtered flow resistance is below the sum of the minimum flow resistance and axis offset.

DIAGNOSIS CONTENT




TROUBLE JUDGMENT


Check Condition
  • The engine is running.
Judgment Criterion
  • DPF load coefficient simulated from pressure drop over air flow is above threshold.


  • DPF load coefficient simulated from DPF temperature is above threshold.

DIAGNOSIS CONTENT




TROUBLE JUDGMENT


Check Condition
  • The engine is running.
Judgment Criterion
  • Unsuccessful regenerations count is above the threshold.

DIAGNOSIS CONTENT




TROUBLE JUDGMENT


Check Condition
  • The engine is running.
Judgment Criterion
  • Accumulated regeneration time is above the threshold.

DIAGNOSIS CONTENT




TROUBLE JUDGMENT


Check Condition
  • The engine is running.
Judgment Criterion
  • The diagnosis code is set.

FAIL SAFE FUNCTION



  • The regeneration in progress is terminated of any further regeneration is stopped.

PROBABLE CAUSE



  • Failed DPF assembly