COOLING FAN RELAY CONTINUITY CHECK <4B11-TURBO>




FAN CONTROL RELAY CHECK



Battery voltage
Terminal No. to be connected to tester
Continuity test result
Not applied
2 - 4
Continuity (Less than 2 Ω)
2 - 5
Open circuit
Connect terminal No.1 and battery (+) terminal.
Connect terminal No.3 and battery (-) terminal.
2 - 4
Open circuit
2 - 5
Continuity (Less than 2 Ω)

RADIATOR FAN RELAY CHECK



Battery voltage
Terminal No. to be connected to tester
Continuity test result
Not applied
2 - 4
Open circuit
Connect terminal No.1 and battery (-) terminal.
Connect terminal No.3 and battery (+) terminal.
Continuity (Less than 2 Ω)

CONDENSER FAN RELAY CHECK



Battery voltage
Terminal No. to be connected to tester
Continuity test result
Not applied
2 - 4
Open circuit
Connect terminal No.1 and battery (-) terminal.
Connect terminal No.3 and battery (+) terminal.
Continuity (Less than 2 Ω)