SERVICE SPECIFICATIONS


Item
Standard value
Limit
Supercharging pressure kPa
68 - 122
-
Initial activation pressure of waste gate actuator
(at the stroke of approximately 1 mm) kPa
78 - 82
-
Waste gate solenoid valve coil resistance (at 20°C) Ω
29 - 35
-
Blow-by heater resistance (at 25 °C) Ω
BWC (vehicles for cold climates)
5.0 - 17.0
-
Inlet manifold distortion of the installation surface mm
4A9
0.15 or less
0.20
Exhaust manifold distortion of the installation surface mm
4A9, 4B10
-
0.70
4B11-Turbo
Cylinder head side
-
0.70
Turbocharger side
-
0.40