ELECTRIC PUMP RELAY CHECK




1.Using a jumper wire, connect the positive battery terminal (+) to the electric pump relay terminal No.3, and the negative battery terminal (-) to the terminal No.1.
2.Check for continuity between the electric pump relay terminals No.2 and No.4.
Jumper wire
Continuity between terminals No.2 and No.4
Connect
Yes (2 Ω or less)
Disconnect
No
3.If defective, replace the electric pump relay.