OSCILLOSCOPE INSPECTION PROCEDURE


Terminal No.
Check item
Inspection condition
Normal condition (Waveform sample)
45
Input shaft speed sensor
Selector lever position: Sport mode (3rd gear)
Driving at constant speed of 50 km/h in 3rd gear (1,800 - 2,100 r/min)
Waveform A
51
Output shaft speed sensor
61
LR solenoid valve

  • Ignition switch: ON
  • Selector lever position: P
  • Engine: Stopped
  • Throttle (Accelerator) opening voltage: 1 V or less

Force drive each solenoid valve (Actuator test)
Waveform B
41
UD solenoid valve
54
2ND solenoid valve
42
OD solenoid valve
48
DCC solenoid valve

WAVEFORM SAMPLE