OSCILLOSCOPE INSPECTION PROCEDURES



Terminal No.
Check item
Check conditions
Normal conditions
Wave patterns
36 - 26
Secondary pulley rotation sensor

  • Selector lever position: D
  • Drive at a constant speed of approx. 20 km/h

Between 0 and 4.5 V, the pulse cycle is constant.


37 - 26
Primary pulley rotation sensor