INSPECTION




  • Check the bushings for wear and deterioration.
  • Check the stabilizer bar for deterioration or damage.
  • Check all bolts for condition and straightness.

STABILIZER LINK BALL JOINT TURNING TORQUE CHECK



1.Move the stabilizer link ball joint stud back and forth for several times, install the stud with nut, and measure the stabilizer link ball joint rotation starting torque using the special tool preload socket (MB990326).
Standard value: 0.5 - 2.9 N·m
2.When the measured value exceeds the standard value, replace the stabilizer link.
3.If the measured value stays within the standard range, and there is looseness or gritty feeling, the component is judged as unusable and should be replaced.

STABILIZER LINK BALL JOINT DUST COVER CHECK


1.Check the dust cover for cracks or damage by pushing it with your finger.
2.If the dust cover is cracked or damaged, replace the stabilizer link (Refer to ).
note If the dust cover has a crack or damage, the ball joint could be damage.