Inspection Procedure 4: SRS warning lamp does not go out.






OPERATION



  • The SRS warning lamp illuminates when the ignition switch is turned to the "ON" position and goes out after approximately 6 to 8 seconds if there is not a malfunction in the SRS system.
  • SRS-ECU sends the SRS warning lamp signal to the combination meter via the CAN communication.
  • As a cause, the failure of CAN bus line, combination meter, or SRS-ECU is suspected.

PROBABLE CAUSES



  • Damaged wiring harness and connectors
  • Combination meter malfunction
  • Malfunction of SRS-ECU

DIAGNOSTIC PROCEDURE


STEP 1. M.U.T.-III CAN bus diagnostics.


Use M.U.T.-III to diagnose the CAN bus lines.

Q. Is the check result normal?

Go to Step 2.
Repair the CAN bus lines (refer to GROUP 54C - Troubleshooting ).

STEP 2. Recheck of the SRS warning lamp


(1)Connect the negative battery terminal.
(2)Ignition switch: ON

Q. Does the lamp stay ON?

Go to Step 3.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).

STEP 3. M.U.T.-III actuator test


Use M.U.T.-III to perform the combination meter actuator tests.
Item No. 07: SRS indicator

Q. Does the SRS warning lamp turn on and off normally?

Go to Step 4.
Replace the combination meter (Refer to GROUP 54A - combination meter ).

STEP 4. Recheck of the SRS warning lamp


(1)Connect the negative battery terminal.
(2)Ignition switch: ON

Q. Does the lamp stay ON?

Check whether the diagnosis code is set. If the diagnosis code is set, troubleshoot the code. If not, replace SRS-ECU (Refer to ).
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).