Inspection Procedure 9: The multi information display screen cannot be changed with the operation of the meter information switch.
| caution | Before replacing the combination meter, be sure to check that the power supply circuit, earth circuit, and communication circuit are normal. |



COMMENTS ON TROUBLE SYMPTOM
PROBABLE CAUSES
- Malfunction of meter information switch
- Malfunction of combination meter
- Damaged harness wires and connectors
DIAGNOSIS PROCEDURE |
STEP 1. M.U.T.-III diagnosis code |
| Check if diagnosis code is set to the combination meter. |
Q.
Is the diagnosis code set?
|
Refer to . |
|
Go to Step 2. |
|
STEP 2. Connector check: C-37 meter information switch connector |
Q.
Is the check result normal?
|
Go to Step 3. |
|
Repair the connector. |
|
STEP 3. Meter information switch check |
Check the meter information switch. Refer to . |
Q.
Is the check result normal?
|
Go to Step 4. |
|
Replace the meter information switch. |
|
STEP 4. Resistance measurement at the C-37 meter information switch connector |
| (1)Disconnect the meter information switch connector, and then measure at the wiring harness side. |
| (2)Measure the resistance from C-37 meter information switch connector terminal No. 4 to body earth. OK: Continuity exists (2 Ω or less) |
Q.
Is the check result normal?
|
Go to Step 6. |
|
Go to Step 5. |
|
STEP 5. Check the wiring harness between the C-37 meter information switch connector terminal No. 4 and the body earth. |
| Check the earth wires for open circuit. |
Q.
Is the check result normal?
|
Go to Step 8. |
|
Repair the wiring harness. |
|
STEP 6. Connector check: C-01 combination meter connector |
Q.
Is the check result normal?
|
Go to Step 7. |
|
Repair the connector. |
|
STEP 7. Check the wiring harness between the C-01 combination meter connector terminal No. 3 and the C-37 meter information switch terminal No. 1. |
| Check the output lines for open circuit. |
Q.
Is the check result normal?
|
Go to Step 8. |
|
Repair the wiring harness. |
|
STEP 8. Retest the system |
| Check that the multi information display screen switches normally when the meter information switch is operated. |
Q.
Is the check result normal?
|
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ). |
|
Replace the combination meter. |
|
Refer to 