Inspection Procedure 11: The picture and sound of external input are not played.
| caution | Whenever the multivision display is replaced, ensure that the power supply circuit and the earthing circuit are normal. (Check that the voltage is 10 V or more.) |



COMMENTS ON TROUBLE SYMPTOM
| note | The connected equipment side or the connection from the audio and video adapter to the equipment may have a problem. Therefore, check that the operation status and the connecting method of the equipment connected to the multivision display and audio and video adapter before performing the diagnosis. |
PROBABLE CAUSES
- The multivision display may be defective
- The audio and video adaptor may be defective
- Damaged harness wires and connectors
DIAGNOSIS |
Required Special Tools:
|
STEP 1. Check of DVD picture |
| Check that the DVD picture is displayed normally. |
Q.
Is the check result normal?
|
Go to Step 2. |
|
Perform the troubleshooting related to the MMCS (Refer to ). |
|
STEP 2. Check the audio and video adapter. |
Check the audio and video adapter.(Refer to ) |
Q.
Is the check result normal?
|
Go to Step 3. |
|
Replace the audio and video adapter. |
|
STEP 3. Connector check: C-142 multivision display connector, C-120 audio and video adaptor connector |
Q.
Is the check result normal?
|
Go to Step 4. |
|
Repair the connector concerned. |
|
STEP 4. Check the wiring harness between C-142 multivision display connector (terminal 47, 63, 48, 64, 49) and C-120 audio and video adaptor connector (terminal 1, 2, 6, 4, 5). |
|
|
Q.
Is the check result normal?
|
Go to Step 5. |
|
Repair the wiring harness. |
|
STEP 5. Temporarily replace the multivision display, and check the trouble symptom. |
| Check that the external input is normal. |
Q.
Is the check result normal?
|
Replace the multivision display. |
|
Replace the audio and video adapter. |
|

Perform the troubleshooting related to the MMCS (Refer to 