Diagnosis Item 17: Diagnose the lines between joint connector (CAN3) and joint connector (CAN4) <RALLIART>
| caution | When servicing a CAN bus line, earth yourself by touching a metal object such as an unpainted water pipe. If you fail to do, a component connected to the CAN bus line may be broken. |





FUNCTION
TROUBLE JUDGEMENT CONDITIONS
TROUBLESHOOTING HINTS
- Malfunction of the connector [joint connector (CAN3), joint connector (CAN4) or intermediate connector failed]
- Malfunction of the wiring harness [open circuit between joint connector (CAN3) and joint connector (CAN4)]
DIAGNOSIS PROCEDURE |
STEP 1. Connector check: C-124 joint connector (CAN3) and A-66 joint connector (CAN4) |
|
Q.
Is the check result normal?
|
Go to Step 2. |
|
Repair the defective connector. |
|
STEP 2. Check the wiring harness between C-124 joint connector (CAN3) and A-66 joint connector (CAN4) |
|
| Disconnect joint connector (CAN3) and joint connector (CAN4), and check the following wiring harness for open circuit |
| (1)The wiring harness between C-124 joint connector (CAN3) terminal No.4 and A-66 joint connector (CAN4) terminal No.5 <CAN_H> OK: Continuity exists (2 Ω or less) |
| (2)The wiring harness between C-124 joint connector (CAN3) terminal No.15 and A-66 joint connector (CAN4) terminal No.16 <CAN_L> OK: Continuity exists (2 Ω or less)
|
Q.
Is the check result normal?
|
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunctions ). |
|
Repair the wiring harness. |
|


Repair the defective connector.