INSPECTION PROCEDURE 4: The Inside/Outside Air Changeover is impossible.














COMMENTS ON TROUBLE SYMPTOM


If the air recirculation cannot be changed by using the inside air/outside air changeover switch, the inside air/outside air changeover motor system may be faulty.

PROBABLE CAUSES



  • Malfunction of the outside/inside air selection damper control motor
  • Malfunction of the heater control panel
  • Damaged the wiring harness or connectors
  • Malfunction of the heater control unit

DIAGNOSIS PROCEDURE


STEP 1. Check the operation of the heater control panel


Check that the rear window defogger switch and air volume control dial can operate.

Q. Is the check result normal?

Go to Step 2.
INSPECTION PROCEDURE 9: Refer to heater control unit power supply system .

STEP 2. M.U.T.-III diagnosis code


Check that the diagnosis code related to the air conditioner is not set.

Q. Is the diagnosis code set?

Carry out the diagnosis code procedures. Refer to .
Go to Step 3.

STEP 3. M.U.T.-III actuator test


Carry out the actuator test. (Refer to ).

  • Item 05: In/out selection damper (Select "position reset".)

Q. Does the blower motor work normally?

This diagnosis is complete.
Go to Step 4.

STEP 4. Connector check: C-147 heater control panel connector and C-60 heater control unit connector


Q. Is the check result normal?

Go to Step 5.
Repair the connector.

STEP 5. Check the wiring harness between C-147 heater control panel connector (terminals 9 and 1) and C-60 heater control unit connector (terminals 9 and 10).



  • Check the heater control panel signal line and earth line for open or short circuit.

Q. Is the check result normal?

Go to Step 6.
Repair the wiring harness.

STEP 6. Connector check: C-59 heater control unit connector and C-107 outside/inside air selection damper control motor connector


Q. Is the check result normal?

Go to Step 7.
Repair the connector.

STEP 7. Check the wiring harness between C-59 heater control unit connector (terminals 29, 24, 27, 25 and 26) and C-107 outside/inside air selection damper control motor connector (terminals 3, 1, 4, 5 and 2).



  • Check the heater control panel signal line and earth line for open or short circuit.

Q. Is the check result normal?

Go to Step 8.
Repair the wiring harness.

STEP 8. Replace the air outside/inside air circulation switching damper motor, and then recheck the trouble symptom.


Check to see that the outside air/inside air circulation switching damper motor operates normally.
note Whenever the motor is replaced, initialise the motor position by using the Actuator Test.

Q. Is the check result normal?

This diagnosis is complete.
Replace the heater control unit.