1.Before inspection, set the vehicle to the pre-inspection condition.
|

|
2.Turn the ignition switch to the "LOCK" (OFF) position and then connect the M.U.T.-III
to the diagnosis connector.
|

|
3.Set the timing light to the power supply line (terminal No. 3) of the ignition coil No.
2.
| note |
The power supply line is looped and also longer than the other ones.
|
4.Start the engine and run it at idle. 5.Check that the idle speed is approximately 600 r/min. 6.Select No. 11 of the M.U.T.-III Actuator test. 7.Check that basic ignition timing is within the standard value. Standard value: 5° BTDC ± 3° 8.If the basic ignition timing is outside the standard value, inspect the MPI system
(Refer to GROUP 13C - Troubleshooting - Inspection chart for trouble symptom ).
| caution |
If the test is not cancelled, a forced driving will continue for
27 minutes. Driving under this condition may damage the engine.
|
9.Cancel the actuator test function item No. 11, Basic ignition timing set mode, on
M.U.T.-III. 10.Check that ignition timing is at the standard value. Standard value: approximately 10° BTDC
| note |
- Ignition timing fluctuates about ±7°, even under normal operating
condition.
- It is automatically further advanced by about 5° from 10° BTDC
at higher altitudes.
- Wait till approximately 1 minute passes after the engine started, and check the
ignition timing when the engine stabilized.
|
11.Remove the timing light. 12.Turn the ignition switch to the "LOCK" (OFF) position and then remove the M.U.T.-III.
|